Property type: Hotel and casino
Location: Hanover, MD
Client: Curtainwall contractor
Case Summary:
Soon after the hotel and casino opened, several panes of curtainwall glass broke in ways that appeared spontaneous. On one day, a number of panes broke at once. Falling glass then broke many panes on a glass canopy below and one pane on a nearby storefront.
The owner brought a claim against the curtainwall contractor, our client. The owner believed the breakage was caused by nickel sulfide (NiS) inclusions in the glass.
What Are Nickel Sulfide Inclusions?
Nickel sulfide inclusions are tiny, stone-like impurities found in small amounts in most window glass. In tempered glass, an inclusion can change size under certain conditions and break the glass spontaneously. Because NiS breaks are real but relatively rare, owners often suspect them first when glass breaks without an obvious cause.
What Façade Consultants Reviewed
- Curtainwall shop drawings
- Project correspondence
- Reports by other consultants
- The punchlist procedure document
- Weather history
Site Investigation
Façade Consultants visited the site while the hotel was occupied and the casino was in full operation. Two swing stages were on the building. Consultants used them to document punchlist items, and workmen used them to make repairs.

Challenge 1: Disagreement Over Punchlist Completion
The consultants and the contractor disagreed about the percentage of punchlist work completed. To support our client’s position, we created a two-part reporting form and trained the workmen to use it:
- Part 1 (upper): Assigned a unique location number to each glass panel and gave workmen a place to record their swing stage position as work progressed.
- Part 2 (lower): Tracked the work on each panel, with work items keyed to an existing repair procedure.

Challenge 2: The Alleged Spontaneous Glass Breakage
We gathered and catalogued every known glass break and identified the most likely cause of each, based on available facts.
Only one break was proven to be caused by a nickel sulfide inclusion. Proof was hard to come by for the rest because neither the hotel nor its consultants stabilized or preserved the glass when it broke. Days passed before the broken pieces fell out of the openings, making diagnosis nearly impossible.

What Actually Broke the Glass
A Wind Event: Many breaks occurred in the same timeframe, which is highly unlikely with nickel sulfide breakage. That pattern points to a weather event. Our research found that a thunderstorm arose suddenly during that period with 46 mph wind gusts. A construction site next door had many small stones on the ground that could be swept up by wind and thrown against the curtainwall.
Supporting evidence: abrasion was found on the exterior face of the inner pane of an insulated glass unit whose outer pane had broken during the storm. This suggests projectiles, probably stones, kept flying after the outer pane shattered and fell out.
Damage From Original Manufacture:In one unit, the exterior view showed an intact outer pane and a broken inner pane with cracks radiating from a corner. Edge damage is a near certainty here, because the glass was glazed into the frame with structural silicone at the factory, long before delivery or installation. The corner was chipped at the factory. The full fracture may have developed later, even after installation.
Other Causes
- Secondary breakage: When glass came down in the storm, it broke canopy glass below.
- Sign penetrations: A few units broke near penetrations for a large sign installed over the glass.
- Construction damage: Some panes were already broken during original construction and were slated for replacement on the punchlist.

Façade Consultants’ Opinion
With proper reporting in place, the client had proof to support its pay request and its representations of project completion.
Our glass breakage analysis showed that only one break could be attributed to nickel sulfide inclusions, while many others could be attributed to original construction damage and the wind event. This put the glass breakage issue in better perspective and helped the client move toward an equitable resolution.
Case Outcome
Pending.
Lessons for Owners, Contractors, and Counsel
- Preserve broken glass immediately. Stabilize the opening and keep the pieces so the break origin can be examined.
- Look for patterns. A cluster of breaks in a short window suggests weather or an external cause, not nickel sulfide.
- Check neighboring conditions. Loose stones or debris at adjacent construction sites can become projectiles.
- Track punchlist work by panel. Unique location numbers and simple forms create a defensible record.
Need a Curtainwall or Glass Breakage Expert?
Pending.